Energy Performance Certificate

42 Beckett Drive, Radley, OX14 3EY

EPC Report

Energy rating

Current: 92 A | Potential: 94 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 92 A Current: 92 A 94 A Potential: 94 A

Environmental impact (CO₂)

Current: 92 | Potential: 94
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 92 Current: 92 94 Potential: 94
Field Value
LMK KEY 9359-3922-7302-8262-7204
ADDRESS1 42 Beckett Drive
ADDRESS2 Radley
ADDRESS3
POSTCODE OX14 3EY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 92
POTENTIAL ENERGY EFFICIENCY 94
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2022-12-15
LOCAL AUTHORITY E07000180
CONSTITUENCY E14001420
COUNTY
LODGEMENT DATE 2022-12-15
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 92
ENVIRONMENT IMPACT POTENTIAL 94
ENERGY CONSUMPTION CURRENT 37
ENERGY CONSUMPTION POTENTIAL 26
CO2 EMISSIONS CURRENT 0.8
CO2 EMISS CURR PER FLOOR AREA 6
CO2 EMISSIONS POTENTIAL 0.6
LIGHTING COST CURRENT 97
LIGHTING COST POTENTIAL 97
HEATING COST CURRENT 330
HEATING COST POTENTIAL 330
HOT WATER COST CURRENT 250
HOT WATER COST POTENTIAL 156
TOTAL FLOOR AREA 133
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.12 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.19 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.39
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 42 Beckett Drive, Radley
LOCAL AUTHORITY LABEL Vale of White Horse
CONSTITUENCY LABEL Oxford West and Abingdon
POSTTOWN ABINGDON
CONSTRUCTION AGE BAND 2020
LODGEMENT DATETIME 2022-12-15 15:30:11
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 13
UPRN 10095810287
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2022.csv
COUNTRY England
REGION E12000008
Address display
Nation ew