Energy Performance Certificate

2, Princes Row, Chester Street, CH7 1EG

EPC Report

Energy rating

Current: 70 C | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 70 | Potential: 71
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 Current: 70 71 Potential: 71
Field Value
LMK KEY 9350-3003-0120-2995-3005
ADDRESS1 2
ADDRESS2 Princes Row
ADDRESS3 Chester Street
POSTCODE CH7 1EG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-12-17
LOCAL AUTHORITY W06000005
CONSTITUENCY W07000094
COUNTY
LODGEMENT DATE 2025-12-17
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 70
ENVIRONMENT IMPACT POTENTIAL 71
ENERGY CONSUMPTION CURRENT 213
ENERGY CONSUMPTION POTENTIAL 197
CO2 EMISSIONS CURRENT 2.4
CO2 EMISS CURR PER FLOOR AREA 39.0
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 44
LIGHTING COST POTENTIAL 44
HEATING COST CURRENT 682
HEATING COST POTENTIAL 682
HOT WATER COST CURRENT 201
HOT WATER COST POTENTIAL 201
TOTAL FLOOR AREA 63
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 43
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.52 W/m²K
FLOOR ENERGY EFF Poor
FLOOR ENV EFF Poor
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Average thermal transmittance 1.29 W/m²K
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.14 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Excellent lighting efficiency
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 2, Princes Row, Chester Street
LOCAL AUTHORITY LABEL Flintshire
CONSTITUENCY LABEL Clwyd East
POSTTOWN Mold
CONSTRUCTION AGE BAND 1870
LODGEMENT DATETIME 2025-12-17 14:25:45
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 10013696040
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2025.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew