Energy Performance Certificate

Second Floor Flat, 6 King Street, Egremont, CH44 8AU

EPC Report

Energy rating

Current: 52 E | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 56 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 Current: 56 67 Potential: 67
Field Value
LMK KEY 9350-2210-6020-2097-6705
ADDRESS1 Second Floor Flat
ADDRESS2 6 King Street
ADDRESS3 Egremont
POSTCODE CH44 8AU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 52
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2023-12-10
LOCAL AUTHORITY E08000015
CONSTITUENCY E14001561
COUNTY
LODGEMENT DATE 2023-12-12
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 56
ENVIRONMENT IMPACT POTENTIAL 67
ENERGY CONSUMPTION CURRENT 355
ENERGY CONSUMPTION POTENTIAL 267
CO2 EMISSIONS CURRENT 2.7
CO2 EMISS CURR PER FLOOR AREA 60
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 97
LIGHTING COST POTENTIAL 121
HEATING COST CURRENT 1239
HEATING COST POTENTIAL 295
HOT WATER COST CURRENT 569
HOT WATER COST POTENTIAL 223
TOTAL FLOOR AREA 45
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 75
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, with additional insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 75% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 2
FLOOR HEIGHT 2.2
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Second Floor Flat, 6 King Street, Egremont
LOCAL AUTHORITY LABEL Wirral
CONSTITUENCY LABEL Wallasey
POSTTOWN Wallasey
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2023-12-12 12:49:49
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 4
LOW ENERGY FIXED LIGHT COUNT 3
UPRN
UPRN SOURCE
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000002
Address display
Nation ew