Energy Performance Certificate

63, Hulmes Road, M40 1GP

EPC Report

Energy rating

Current: 21 F | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 21 F Current: 21 F 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 16 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 16 Current: 16 78 Potential: 78
Field Value
LMK KEY 9348-7035-7296-5788-6960
ADDRESS1 63, Hulmes Road
ADDRESS2
ADDRESS3
POSTCODE M40 1GP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 21
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2018-06-14
LOCAL AUTHORITY E08000003
CONSTITUENCY E14001352
COUNTY
LODGEMENT DATE 2018-06-14
TRANSACTION TYPE Non-marketed sale
ENVIRONMENT IMPACT CURRENT 16
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 593
ENERGY CONSUMPTION POTENTIAL 109
CO2 EMISSIONS CURRENT 17
CO2 EMISS CURR PER FLOOR AREA 105
CO2 EMISSIONS POTENTIAL 3.1
LIGHTING COST CURRENT 140
LIGHTING COST POTENTIAL 87
HEATING COST CURRENT 2784
HEATING COST POTENTIAL 696
HOT WATER COST CURRENT 311
HOT WATER COST POTENTIAL 79
TOTAL FLOOR AREA 159
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 35
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 35% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.02
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 63, Hulmes Road
LOCAL AUTHORITY LABEL Manchester
CONSTITUENCY LABEL Manchester Central
POSTTOWN MANCHESTER
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2018-06-14 18:52:58
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 17