Energy Performance Certificate

14 Montserrat Road, SW15 2LA

EPC Report

Energy rating

Current: 72 C | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 C Current: 72 C 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 68 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 Current: 68 75 Potential: 75
Field Value
LMK KEY 9335-3428-3500-0883-3206
ADDRESS1 14 Montserrat Road
ADDRESS2
ADDRESS3
POSTCODE SW15 2LA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 72
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-08-07
LOCAL AUTHORITY E09000032
CONSTITUENCY E14001434
COUNTY
LODGEMENT DATE 2025-08-08
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 68
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 130
ENERGY CONSUMPTION POTENTIAL 97
CO2 EMISSIONS CURRENT 4.9
CO2 EMISS CURR PER FLOOR AREA 24
CO2 EMISSIONS POTENTIAL 3.7
LIGHTING COST CURRENT 132
LIGHTING COST POTENTIAL 132
HEATING COST CURRENT 1387
HEATING COST POTENTIAL 1070
HOT WATER COST CURRENT 253
HOT WATER COST POTENTIAL 254
TOTAL FLOOR AREA 205
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 85
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 70
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.94
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 14 Montserrat Road
LOCAL AUTHORITY LABEL Wandsworth
CONSTITUENCY LABEL Putney
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2025-08-08 10:30:51
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 46
LOW ENERGY FIXED LIGHT COUNT 32
UPRN 100022672659
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000007
Address display
Nation ew