Energy Performance Certificate

82 St. Aubyns, Goldsithney, TR20 9LS

EPC Report

Energy rating

Current: 86 B | Potential: 95 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 B Current: 86 B 95 A Potential: 95 A

Environmental impact (CO₂)

Current: 88 | Potential: 95
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 88 Current: 88 95 Potential: 95
Field Value
LMK KEY 9320-2365-2190-2294-0115
ADDRESS1 82 St. Aubyns
ADDRESS2 Goldsithney
ADDRESS3
POSTCODE TR20 9LS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 86
POTENTIAL ENERGY EFFICIENCY 95
PROPERTY TYPE Bungalow
BUILT FORM End-Terrace
INSPECTION DATE 2024-11-15
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001511
COUNTY
LODGEMENT DATE 2024-11-18
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 88
ENVIRONMENT IMPACT POTENTIAL 95
ENERGY CONSUMPTION CURRENT 51
ENERGY CONSUMPTION POTENTIAL -9
CO2 EMISSIONS CURRENT 0.4
CO2 EMISS CURR PER FLOOR AREA 9
CO2 EMISSIONS POTENTIAL -0.1
LIGHTING COST CURRENT 59
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 489
HEATING COST POTENTIAL 399
HOT WATER COST CURRENT 263
HOT WATER COST POTENTIAL 107
TOTAL FLOOR AREA 50
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE not defined
GLAZED AREA Much Less Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 40
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 82 St. Aubyns, Goldsithney
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL St Ives
POSTTOWN PENZANCE
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2024-11-18 09:23:38
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100040115204
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000009
Address display
Nation ew