Energy Performance Certificate

Flat 4, 4 Cecil Street, FY8 5NN

EPC Report

Energy rating

Current: 54 E | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 88 | Potential: 93
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 88 Current: 88 93 Potential: 93
Field Value
LMK KEY 9320-2313-3590-2405-7645
ADDRESS1 Flat 4
ADDRESS2 4 Cecil Street
ADDRESS3
POSTCODE FY8 5NN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Flat
BUILT FORM Not Recorded
INSPECTION DATE 2025-11-07
LOCAL AUTHORITY E07000119
CONSTITUENCY E14001242
COUNTY
LODGEMENT DATE 2025-11-07
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 88
ENVIRONMENT IMPACT POTENTIAL 93
ENERGY CONSUMPTION CURRENT 146
ENERGY CONSUMPTION POTENTIAL 86
CO2 EMISSIONS CURRENT 1.0
CO2 EMISS CURR PER FLOOR AREA 14
CO2 EMISSIONS POTENTIAL 0.6
LIGHTING COST CURRENT 57
LIGHTING COST POTENTIAL 66
HEATING COST CURRENT 1531
HEATING COST POTENTIAL 481
HOT WATER COST CURRENT 358
HOT WATER COST POTENTIAL 412
TOTAL FLOOR AREA 73
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.7
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 4, 4 Cecil Street
LOCAL AUTHORITY LABEL Fylde
CONSTITUENCY LABEL Fylde
POSTTOWN LYTHAM ST. ANNES
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2025-11-07 17:40:26
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6