Energy Performance Certificate

LOW ROAD COTTAGE, MINOR ROAD THROUGH BRIDEKIRK, BRIDEKIRK, CA13 0PE

EPC Report

Energy rating

Current: 15 G | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 15 G Current: 15 G 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 1 | Potential: 44
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 Current: 1 44 Potential: 44
Field Value
LMK KEY 9320-2193-3000-2920-1085
ADDRESS1 LOW ROAD COTTAGE
ADDRESS2 MINOR ROAD THROUGH BRIDEKIRK
ADDRESS3 BRIDEKIRK
POSTCODE CA13 0PE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 15
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2020-10-27
LOCAL AUTHORITY E06000063
CONSTITUENCY E14001424
COUNTY
LODGEMENT DATE 2020-10-29
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 1
ENVIRONMENT IMPACT POTENTIAL 44
ENERGY CONSUMPTION CURRENT 1237
ENERGY CONSUMPTION POTENTIAL 431
CO2 EMISSIONS CURRENT 14
CO2 EMISS CURR PER FLOOR AREA 242
CO2 EMISSIONS POTENTIAL 4.9
LIGHTING COST CURRENT 56
LIGHTING COST POTENTIAL 56
HEATING COST CURRENT 1733
HEATING COST POTENTIAL 799
HOT WATER COST CURRENT 801
HOT WATER COST POTENTIAL 104
TOTAL FLOOR AREA 59
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, coal
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.25
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS LOW ROAD COTTAGE, MINOR ROAD THROUGH BRIDEKIRK, BRIDEKIRK
LOCAL AUTHORITY LABEL Cumberland
CONSTITUENCY LABEL Penrith and Solway
POSTTOWN BRIDEKIRK
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2020-10-29 15:54:45
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 10000886421
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000002
Address display
Nation ew