Energy Performance Certificate

15, Horne Close, CV21 4ET

EPC Report

Energy rating

Current: 77 C | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 C Current: 77 C 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 79 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 Current: 79 82 Potential: 82
Field Value
LMK KEY 9319-2867-7199-9397-3785
ADDRESS1 15, Horne Close
ADDRESS2
ADDRESS3
POSTCODE CV21 4ET
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 77
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2013-11-13
LOCAL AUTHORITY E07000220
CONSTITUENCY E14001453
COUNTY
LODGEMENT DATE 2013-11-29
TRANSACTION TYPE FiT application
ENVIRONMENT IMPACT CURRENT 79
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 104
ENERGY CONSUMPTION POTENTIAL 93
CO2 EMISSIONS CURRENT 3.5
CO2 EMISS CURR PER FLOOR AREA 18
CO2 EMISSIONS POTENTIAL 3.1
LIGHTING COST CURRENT 83
LIGHTING COST POTENTIAL 83
HEATING COST CURRENT 1014
HEATING COST POTENTIAL 1016
HOT WATER COST CURRENT 299
HOT WATER COST POTENTIAL 200
TOTAL FLOOR AREA 192
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and at least two room thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and at least two room thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 15, Horne Close
LOCAL AUTHORITY LABEL Rugby
CONSTITUENCY LABEL Rugby
POSTTOWN RUGBY
CONSTRUCTION AGE BAND England and Wales: 2007 onwards
LODGEMENT DATETIME 2013-11-29 09:09:49
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 29
LOW ENERGY FIXED LIGHT COUNT 29
UPRN 10010517072
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000005
Address display
Nation ew