Energy Performance Certificate
2, Hyatts Way, Bishops Cleeve, GL52 8PD
Energy rating
Current: 37 F | Potential: 86 B
Environmental impact (CO₂)
Current: 23
| Potential: 84
| Field | Value |
|---|---|
| LMK KEY | 9318-8090-7259-3115-6950 |
| ADDRESS1 | 2, Hyatts Way |
| ADDRESS2 | Bishops Cleeve |
| ADDRESS3 | — |
| POSTCODE | GL52 8PD |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | F |
| POTENTIAL ENERGY RATING | B |
| CURRENT ENERGY EFFICIENCY | 37 |
| POTENTIAL ENERGY EFFICIENCY | 86 |
| PROPERTY TYPE | House |
| BUILT FORM | Semi-Detached |
| INSPECTION DATE | 2015-01-19 |
| LOCAL AUTHORITY | E07000083 |
| CONSTITUENCY | E14001542 |
| COUNTY | — |
| LODGEMENT DATE | 2015-01-19 |
| TRANSACTION TYPE | Marketed sale |
| ENVIRONMENT IMPACT CURRENT | 23 |
| ENVIRONMENT IMPACT POTENTIAL | 84 |
| ENERGY CONSUMPTION CURRENT | 622 |
| ENERGY CONSUMPTION POTENTIAL | 84 |
| CO2 EMISSIONS CURRENT | 8.4 |
| CO2 EMISS CURR PER FLOOR AREA | 106 |
| CO2 EMISSIONS POTENTIAL | 1.2 |
| LIGHTING COST CURRENT | 85 |
| LIGHTING COST POTENTIAL | 51 |
| HEATING COST CURRENT | 1061 |
| HEATING COST POTENTIAL | 428 |
| HOT WATER COST CURRENT | 307 |
| HOT WATER COST POTENTIAL | 73 |
| TOTAL FLOOR AREA | 79 |
| ENERGY TARIFF | dual |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 2 |
| MAIN HEATING CONTROLS | Manual charge control |
| MULTI GLAZE PROPORTION | 90 |
| GLAZED TYPE | double glazing installed before 2002 |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 0 |
| NUMBER HABITABLE ROOMS | 5 |
| NUMBER HEATED ROOMS | 3 |
| LOW ENERGY LIGHTING | 50 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Mostly double glazing |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| WALLS DESCRIPTION | Cavity wall, as built, no insulation (assumed) |
| WALLS ENERGY EFF | Poor |
| WALLS ENV EFF | Poor |
| SECONDHEAT DESCRIPTION | Room heaters, mains gas |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, 100 mm loft insulation |
| ROOF ENERGY EFF | Average |
| ROOF ENV EFF | Average |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Very Poor |
| MAINHEATCONT DESCRIPTION | Manual charge control |
| MAINHEATC ENERGY EFF | Poor |
| MAINHEATC ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 50% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| MAIN FUEL | electricity (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.29 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | 2, Hyatts Way, Bishops Cleeve |
| LOCAL AUTHORITY LABEL | Tewkesbury |
| CONSTITUENCY LABEL | Tewkesbury |
| POSTTOWN | CHELTENHAM |
| CONSTRUCTION AGE BAND | England and Wales: 1930-1949 |
| LODGEMENT DATETIME | 2015-01-19 17:51:21 |
| TENURE | owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | 12 |
| LOW ENERGY FIXED LIGHT COUNT | 6 |
| UPRN | 100120536521 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2015.csv |
| COUNTRY | England |
| REGION | E12000009 |
| Address display | — |
| Nation | ew |