Energy Performance Certificate
Flat 21, 173 Lozells Road, B19 1RN
Energy rating
Current: 52 E | Potential: 58 D
Environmental impact (CO₂)
Current: 49
| Potential: 55
| Field | Value |
|---|---|
| LMK KEY | 9288-9039-7261-5331-9984 |
| ADDRESS1 | Flat 21 |
| ADDRESS2 | 173 Lozells Road |
| ADDRESS3 | — |
| POSTCODE | B19 1RN |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | E |
| POTENTIAL ENERGY RATING | D |
| CURRENT ENERGY EFFICIENCY | 52 |
| POTENTIAL ENERGY EFFICIENCY | 58 |
| PROPERTY TYPE | Flat |
| BUILT FORM | Semi-Detached |
| INSPECTION DATE | 2019-09-18 |
| LOCAL AUTHORITY | E08000025 |
| CONSTITUENCY | E14001098 |
| COUNTY | — |
| LODGEMENT DATE | 2019-09-23 |
| TRANSACTION TYPE | ECO assessment |
| ENVIRONMENT IMPACT CURRENT | 49 |
| ENVIRONMENT IMPACT POTENTIAL | 55 |
| ENERGY CONSUMPTION CURRENT | 511 |
| ENERGY CONSUMPTION POTENTIAL | 441 |
| CO2 EMISSIONS CURRENT | 2.9 |
| CO2 EMISS CURR PER FLOOR AREA | 90 |
| CO2 EMISSIONS POTENTIAL | 2.5 |
| LIGHTING COST CURRENT | 57 |
| LIGHTING COST POTENTIAL | 29 |
| HEATING COST CURRENT | 517 |
| HEATING COST POTENTIAL | 468 |
| HOT WATER COST CURRENT | 106 |
| HOT WATER COST POTENTIAL | 94 |
| TOTAL FLOOR AREA | 33 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | 3 |
| FLAT TOP STOREY | Y |
| FLAT STOREY COUNT | 1 |
| MAIN HEATING CONTROLS | Flat rate charging, no thermostatic control of room temperature |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 0 |
| NUMBER HABITABLE ROOMS | 2 |
| NUMBER HEATED ROOMS | 2 |
| LOW ENERGY LIGHTING | 0 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | Community scheme |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| WALLS DESCRIPTION | Cavity wall, as built, no insulation (assumed) |
| WALLS ENERGY EFF | Poor |
| WALLS ENV EFF | Poor |
| SECONDHEAT DESCRIPTION | Room heaters, electric |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, limited insulation (assumed) |
| ROOF ENERGY EFF | Very Poor |
| ROOF ENV EFF | Very Poor |
| MAINHEAT DESCRIPTION | Community scheme |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Flat rate charging, no thermostatic control of room temperature |
| MAINHEATC ENERGY EFF | Very Poor |
| MAINHEATC ENV EFF | Very Poor |
| LIGHTING DESCRIPTION | No low energy lighting |
| LIGHTING ENERGY EFF | Very Poor |
| LIGHTING ENV EFF | Very Poor |
| MAIN FUEL | mains gas (community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | unheated corridor |
| UNHEATED CORRIDOR LENGTH | 10.86 |
| FLOOR HEIGHT | 2.7 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | Flat 21, 173 Lozells Road |
| LOCAL AUTHORITY LABEL | Birmingham |
| CONSTITUENCY LABEL | Birmingham Perry Barr |
| POSTTOWN | BIRMINGHAM |
| CONSTRUCTION AGE BAND | England and Wales: 1967-1975 |
| LODGEMENT DATETIME | 2019-09-23 20:44:55 |
| TENURE | rented (social) |
| FIXED LIGHTING OUTLETS COUNT | 5 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| UPRN | 100071436359 |
| UPRN SOURCE | Address Matched |
| REPORT TYPE | 2 |
| Source file | certificates-2019.csv |
| COUNTRY | England |
| REGION | E12000005 |
| Address display | — |
| Nation | ew |