Energy Performance Certificate

34, Falkland, WN8 6RA

EPC Report

Energy rating

Current: 30 F | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 F Current: 30 F 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 28 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 28 Current: 28 89 Potential: 89
Field Value
LMK KEY 9288-3023-7295-3065-1990
ADDRESS1 34, Falkland
ADDRESS2
ADDRESS3
POSTCODE WN8 6RA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 30
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2015-05-18
LOCAL AUTHORITY E07000127
CONSTITUENCY E14001577
COUNTY
LODGEMENT DATE 2015-05-18
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 28
ENVIRONMENT IMPACT POTENTIAL 89
ENERGY CONSUMPTION CURRENT 539
ENERGY CONSUMPTION POTENTIAL 65
CO2 EMISSIONS CURRENT 8.5
CO2 EMISS CURR PER FLOOR AREA 94
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 113
LIGHTING COST POTENTIAL 56
HEATING COST CURRENT 1380
HEATING COST POTENTIAL 379
HOT WATER COST CURRENT 426
HOT WATER COST POTENTIAL 76
TOTAL FLOOR AREA 90
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 34, Falkland
LOCAL AUTHORITY LABEL West Lancashire
CONSTITUENCY LABEL West Lancashire
POSTTOWN SKELMERSDALE
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-05-18 21:40:26
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100010679688
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000002
Address display
Nation ew