Energy Performance Certificate

43 Fremount Drive, NG8 3GH

EPC Report

Energy rating

Current: 69 C | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 C Current: 69 C 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 79 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 Current: 79 83 Potential: 83
Field Value
LMK KEY 9273-3048-1208-3535-5200
ADDRESS1 43 Fremount Drive
ADDRESS2
ADDRESS3
POSTCODE NG8 3GH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 69
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2025-08-13
LOCAL AUTHORITY E06000018
CONSTITUENCY E14001412
COUNTY
LODGEMENT DATE 2025-08-18
TRANSACTION TYPE Grant scheme
ENVIRONMENT IMPACT CURRENT 79
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 162
ENERGY CONSUMPTION POTENTIAL 120
CO2 EMISSIONS CURRENT 1.6
CO2 EMISS CURR PER FLOOR AREA 27
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 46
LIGHTING COST POTENTIAL 46
HEATING COST CURRENT 651
HEATING COST POTENTIAL 553
HOT WATER COST CURRENT 234
HOT WATER COST POTENTIAL 234
TOTAL FLOOR AREA 60
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 400+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 43 Fremount Drive
LOCAL AUTHORITY LABEL Nottingham
CONSTITUENCY LABEL Nottingham South
POSTTOWN NOTTINGHAM
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2025-08-18 10:56:09
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100031547737
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000004
Address display
Nation ew