Energy Performance Certificate

The Cottage, Great Green, Thurston, IP31 3SL

EPC Report

Energy rating

Current: 33 F | Potential: 46 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 F Current: 33 F 46 E Potential: 46 E

Environmental impact (CO₂)

Current: 32 | Potential: 41
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 41 Potential: 41
Field Value
LMK KEY 9270-2753-3390-2199-2885
ADDRESS1 The Cottage
ADDRESS2 Great Green
ADDRESS3 Thurston
POSTCODE IP31 3SL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 33
POTENTIAL ENERGY EFFICIENCY 46
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2021-11-17
LOCAL AUTHORITY E07000203
CONSTITUENCY E14001146
COUNTY
LODGEMENT DATE 2022-06-28
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 41
ENERGY CONSUMPTION CURRENT 330
ENERGY CONSUMPTION POTENTIAL 243
CO2 EMISSIONS CURRENT 8.8
CO2 EMISS CURR PER FLOOR AREA 81
CO2 EMISSIONS POTENTIAL 6.9
LIGHTING COST CURRENT 152
LIGHTING COST POTENTIAL 91
HEATING COST CURRENT 1401
HEATING COST POTENTIAL 1333
HOT WATER COST CURRENT 135
HOT WATER COST POTENTIAL 87
TOTAL FLOOR AREA 109
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 95
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.13
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS The Cottage, Great Green, Thurston
LOCAL AUTHORITY LABEL Mid Suffolk
CONSTITUENCY LABEL Bury St Edmunds and Stowmarket
POSTTOWN BURY ST. EDMUNDS
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2022-06-28 16:12:30
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 24
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 200003815737
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000006
Address display
Nation ew