Energy Performance Certificate

Cliff Cote, Prospect Field, Robin Hoods Bay, YO22 4RH

EPC Report

Energy rating

Current: 13 G | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 13 G Current: 13 G 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 1 | Potential: 108
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 Current: 1 108 Potential: 108
Field Value
LMK KEY 9268-3978-7272-1527-0914
ADDRESS1 Cliff Cote
ADDRESS2 Prospect Field
ADDRESS3 Robin Hoods Bay
POSTCODE YO22 4RH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 13
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2013-12-16
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001461
COUNTY
LODGEMENT DATE 2013-12-18
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 1
ENVIRONMENT IMPACT POTENTIAL 108
ENERGY CONSUMPTION CURRENT 1017
ENERGY CONSUMPTION POTENTIAL 108
CO2 EMISSIONS CURRENT 13
CO2 EMISS CURR PER FLOOR AREA 276
CO2 EMISSIONS POTENTIAL -0.4
LIGHTING COST CURRENT 41
LIGHTING COST POTENTIAL 41
HEATING COST CURRENT 1524
HEATING COST POTENTIAL 372
HOT WATER COST CURRENT 212
HOT WATER COST POTENTIAL 100
TOTAL FLOOR AREA 46
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 50
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 60
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, coal
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 60% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL house coal (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.44
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Cliff Cote, Prospect Field, Robin Hoods Bay
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Scarborough and Whitby
POSTTOWN WHITBY
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2013-12-18 16:57:33
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100050500814
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000003
Address display
Nation ew