Energy Performance Certificate

Apartment 97, Hampton House, Michael Road, SW6 2RN

EPC Report

Energy rating

Current: 84 B | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 84 B Current: 84 B 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 89 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 89 Current: 89 89 Potential: 89
Field Value
LMK KEY 9268-3903-9302-7232-7200
ADDRESS1 Apartment 97
ADDRESS2 Hampton House
ADDRESS3 Michael Road
POSTCODE SW6 2RN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 84
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-12-16
LOCAL AUTHORITY E09000013
CONSTITUENCY E14001160
COUNTY
LODGEMENT DATE 2022-12-16
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 89
ENVIRONMENT IMPACT POTENTIAL 89
ENERGY CONSUMPTION CURRENT 78
ENERGY CONSUMPTION POTENTIAL 78
CO2 EMISSIONS CURRENT 0.7
CO2 EMISS CURR PER FLOOR AREA 14
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 50
LIGHTING COST POTENTIAL 50
HEATING COST CURRENT 129
HEATING COST POTENTIAL 129
HOT WATER COST CURRENT 78
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 53
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Flat rate charging, programmer and at least two room thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.15 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (other premises above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Flat rate charging, programmer and at least two room thermostats
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Apartment 97, Hampton House, Michael Road
LOCAL AUTHORITY LABEL Hammersmith and Fulham
CONSTITUENCY LABEL Chelsea and Fulham
POSTTOWN London
CONSTRUCTION AGE BAND 2019
LODGEMENT DATETIME 2022-12-16 15:06:24
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 34171611
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2022.csv
COUNTRY England
REGION E12000007
Address display
Nation ew