Energy Performance Certificate

Flat 5 Juxon House, Juxon Street, OX2 6DR

EPC Report

Energy rating

Current: 41 E | Potential: 68 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 E Current: 41 E 68 D Potential: 68 D

Environmental impact (CO₂)

Current: 48 | Potential: 47
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 47 Potential: 47
Field Value
LMK KEY 9268-2019-6271-5256-2920
ADDRESS1 Flat 5 Juxon House
ADDRESS2 Juxon Street
ADDRESS3
POSTCODE OX2 6DR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 41
POTENTIAL ENERGY EFFICIENCY 68
PROPERTY TYPE Maisonette
BUILT FORM End-Terrace
INSPECTION DATE 2016-09-16
LOCAL AUTHORITY E07000178
CONSTITUENCY E14001420
COUNTY
LODGEMENT DATE 2018-02-21
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 48
ENVIRONMENT IMPACT POTENTIAL 47
ENERGY CONSUMPTION CURRENT 355
ENERGY CONSUMPTION POTENTIAL 369
CO2 EMISSIONS CURRENT 4.3
CO2 EMISS CURR PER FLOOR AREA 60
CO2 EMISSIONS POTENTIAL 4.5
LIGHTING COST CURRENT 63
LIGHTING COST POTENTIAL 70
HEATING COST CURRENT 972
HEATING COST POTENTIAL 525
HOT WATER COST CURRENT 315
HOT WATER COST POTENTIAL 153
TOTAL FLOOR AREA 73
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 82
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION To external air, insulated
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 82% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.42
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 5 Juxon House, Juxon Street
LOCAL AUTHORITY LABEL Oxford
CONSTITUENCY LABEL Oxford West and Abingdon
POSTTOWN OXFORD
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2018-02-21 09:42:10
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 10024244721
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000008
Address display
Nation ew