Energy Performance Certificate

8 Pinfold Close, Skelton, CA11 9SB

EPC Report

Energy rating

Current: 94 A | Potential: 119 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 94 A Current: 94 A 119 A Potential: 119 A

Environmental impact (CO₂)

Current: 94 | Potential: 117
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 94 Current: 94 117 Potential: 117
Field Value
LMK KEY 9265-0905-0372-0652-4204
ADDRESS1 8 Pinfold Close
ADDRESS2 Skelton
ADDRESS3
POSTCODE CA11 9SB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 94
POTENTIAL ENERGY EFFICIENCY 119
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2022-12-16
LOCAL AUTHORITY E06000064
CONSTITUENCY E14001424
COUNTY
LODGEMENT DATE 2022-12-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 94
ENVIRONMENT IMPACT POTENTIAL 117
ENERGY CONSUMPTION CURRENT 51
ENERGY CONSUMPTION POTENTIAL -108
CO2 EMISSIONS CURRENT 0.7
CO2 EMISS CURR PER FLOOR AREA 9
CO2 EMISSIONS POTENTIAL -1.4
LIGHTING COST CURRENT 74
LIGHTING COST POTENTIAL 74
HEATING COST CURRENT 276
HEATING COST POTENTIAL 277
HOT WATER COST CURRENT 244
HOT WATER COST POTENTIAL 146
TOTAL FLOOR AREA 78
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.11 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.15 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.1 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, Underfloor heating, pipes in screed above insulation, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.343
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 8 Pinfold Close, Skelton
LOCAL AUTHORITY LABEL Westmorland and Furness
CONSTITUENCY LABEL Penrith and Solway
POSTTOWN PENRITH
CONSTRUCTION AGE BAND 2022
LODGEMENT DATETIME 2022-12-19 11:29:39
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 23
LOW ENERGY FIXED LIGHT COUNT 23
UPRN 10070545005
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2022.csv
COUNTRY England
REGION E12000002
Address display
Nation ew