Energy Performance Certificate

1, Dyers Yard, Ramsbury, SN8 2QU

EPC Report

Energy rating

Current: 18 G | Potential: 39 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 18 G Current: 18 G 39 E Potential: 39 E

Environmental impact (CO₂)

Current: 67 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 Current: 67 86 Potential: 86
Field Value
LMK KEY 9258-7076-7225-5111-3940
ADDRESS1 1, Dyers Yard
ADDRESS2 Ramsbury
ADDRESS3
POSTCODE SN8 2QU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 18
POTENTIAL ENERGY EFFICIENCY 39
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2019-05-15
LOCAL AUTHORITY E06000054
CONSTITUENCY E14001217
COUNTY
LODGEMENT DATE 2019-05-21
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 67
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 603
ENERGY CONSUMPTION POTENTIAL 406
CO2 EMISSIONS CURRENT 3.1
CO2 EMISS CURR PER FLOOR AREA 39
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 88
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 1854
HEATING COST POTENTIAL 1568
HOT WATER COST CURRENT 357
HOT WATER COST POTENTIAL 176
TOTAL FLOOR AREA 80
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, wood logs
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL wood logs
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.25
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Dyers Yard, Ramsbury
LOCAL AUTHORITY LABEL Wiltshire
CONSTITUENCY LABEL East Wiltshire
POSTTOWN MARLBOROUGH
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2019-05-21 09:08:36
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 200001179349
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000009
Address display
Nation ew