Energy Performance Certificate

3, Pit Lane, Gedney Drove End, PE12 9PG

EPC Report

Energy rating

Current: 22 F | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 22 F Current: 22 F 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 32 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 69 Potential: 69
Field Value
LMK KEY 9258-6061-7297-0867-2940
ADDRESS1 3, Pit Lane
ADDRESS2 Gedney Drove End
ADDRESS3
POSTCODE PE12 9PG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 22
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2013-03-15
LOCAL AUTHORITY E07000140
CONSTITUENCY E14001487
COUNTY
LODGEMENT DATE 2013-03-17
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 620
ENERGY CONSUMPTION POTENTIAL 247
CO2 EMISSIONS CURRENT 5.5
CO2 EMISS CURR PER FLOOR AREA 110
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 57
LIGHTING COST POTENTIAL 33
HEATING COST CURRENT 946
HEATING COST POTENTIAL 348
HOT WATER COST CURRENT 412
HOT WATER COST POTENTIAL 66
TOTAL FLOOR AREA 51
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 14
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 14% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL To be used only when there is no heating/hot-water system
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.34
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3, Pit Lane, Gedney Drove End
LOCAL AUTHORITY LABEL South Holland
CONSTITUENCY LABEL South Holland and The Deepings
POSTTOWN SPALDING
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2013-03-17 12:51:01
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100030891717
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000004
Address display
Nation ew