Energy Performance Certificate

28, Denewood Close, Willington, DL15 0HB

EPC Report

Energy rating

Current: 63 D | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 D Current: 63 D 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 57 | Potential: 71
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 Current: 57 71 Potential: 71
Field Value
LMK KEY 9258-4083-7222-0143-6964
ADDRESS1 28, Denewood Close
ADDRESS2 Willington
ADDRESS3
POSTCODE DL15 0HB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 63
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2017-02-15
LOCAL AUTHORITY E06000047
CONSTITUENCY E14001173
COUNTY
LODGEMENT DATE 2017-02-20
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 57
ENVIRONMENT IMPACT POTENTIAL 71
ENERGY CONSUMPTION CURRENT 305
ENERGY CONSUMPTION POTENTIAL 217
CO2 EMISSIONS CURRENT 5.1
CO2 EMISS CURR PER FLOOR AREA 54
CO2 EMISSIONS POTENTIAL 3.7
LIGHTING COST CURRENT 121
LIGHTING COST POTENTIAL 61
HEATING COST CURRENT 894
HEATING COST POTENTIAL 862
HOT WATER COST CURRENT 115
HOT WATER COST POTENTIAL 79
TOTAL FLOOR AREA 95
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 28, Denewood Close, Willington
LOCAL AUTHORITY LABEL County Durham
CONSTITUENCY LABEL City of Durham
POSTTOWN CROOK
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2017-02-20 15:08:06
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 10000805710
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000001
Address display
Nation ew