Energy Performance Certificate

23, Normanton View, WF6 1PJ

EPC Report

Energy rating

Current: 54 E | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 48 | Potential: 87
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 87 Potential: 87
Field Value
LMK KEY 9253-2859-6495-9623-2525
ADDRESS1 23, Normanton View
ADDRESS2
ADDRESS3
POSTCODE WF6 1PJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2017-11-21
LOCAL AUTHORITY E08000036
CONSTITUENCY E14001383
COUNTY
LODGEMENT DATE 2017-11-21
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 48
ENVIRONMENT IMPACT POTENTIAL 87
ENERGY CONSUMPTION CURRENT 389
ENERGY CONSUMPTION POTENTIAL 92
CO2 EMISSIONS CURRENT 4.2
CO2 EMISS CURR PER FLOOR AREA 69
CO2 EMISSIONS POTENTIAL 1.0
LIGHTING COST CURRENT 86
LIGHTING COST POTENTIAL 43
HEATING COST CURRENT 618
HEATING COST POTENTIAL 384
HOT WATER COST CURRENT 227
HOT WATER COST POTENTIAL 67
TOTAL FLOOR AREA 60
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 1
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 23, Normanton View
LOCAL AUTHORITY LABEL Wakefield
CONSTITUENCY LABEL Normanton and Hemsworth
POSTTOWN NORMANTON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2017-11-21 09:51:56
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 63081361
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000003
Address display
Nation ew