Energy Performance Certificate

Flat 42, 73, Upper Richmond Road, SW15 2SR

EPC Report

Energy rating

Current: 75 C | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 78 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 Current: 78 78 Potential: 78
Field Value
LMK KEY 9253-2801-6696-9928-8671
ADDRESS1 Flat 42
ADDRESS2 73, Upper Richmond Road
ADDRESS3
POSTCODE SW15 2SR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 75
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-11-29
LOCAL AUTHORITY E09000032
CONSTITUENCY E14001434
COUNTY
LODGEMENT DATE 2018-11-30
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 78
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 158
ENERGY CONSUMPTION POTENTIAL 158
CO2 EMISSIONS CURRENT 1.5
CO2 EMISS CURR PER FLOOR AREA 27
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 46
LIGHTING COST POTENTIAL 51
HEATING COST CURRENT 130
HEATING COST POTENTIAL 78
HOT WATER COST CURRENT 294
HOT WATER COST POTENTIAL 152
TOTAL FLOOR AREA 55
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION System built, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and room thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 6.1
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 42, 73, Upper Richmond Road
LOCAL AUTHORITY LABEL Wandsworth
CONSTITUENCY LABEL Putney
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2018-11-30 23:38:23
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 121052363
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000007
Address display
Nation ew