Energy Performance Certificate

8, Kennedy Close, Petts Wood, BR5 1HP

EPC Report

Energy rating

Current: 62 D | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 D Current: 62 D 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 55 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 Current: 55 73 Potential: 73
Field Value
LMK KEY 9246-2829-6308-9523-5945
ADDRESS1 8, Kennedy Close
ADDRESS2 Petts Wood
ADDRESS3
POSTCODE BR5 1HP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 62
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2017-10-21
LOCAL AUTHORITY E09000006
CONSTITUENCY E14001417
COUNTY
LODGEMENT DATE 2017-12-12
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 55
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 245
ENERGY CONSUMPTION POTENTIAL 135
CO2 EMISSIONS CURRENT 4.9
CO2 EMISS CURR PER FLOOR AREA 43
CO2 EMISSIONS POTENTIAL 2.8
LIGHTING COST CURRENT 70
LIGHTING COST POTENTIAL 70
HEATING COST CURRENT 853
HEATING COST POTENTIAL 675
HOT WATER COST CURRENT 140
HOT WATER COST POTENTIAL 88
TOTAL FLOOR AREA 114
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.44
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 8, Kennedy Close, Petts Wood
LOCAL AUTHORITY LABEL Bromley
CONSTITUENCY LABEL Orpington
POSTTOWN ORPINGTON
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2017-12-12 14:44:11
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100020463638
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000007
Address display
Nation ew