Energy Performance Certificate

55 BLAKE CLOSE, CANNOCK, WS11 5UB

EPC Report

Energy rating

Current: 35 F | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 F Current: 35 F 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 19 | Potential: 52
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 19 Current: 19 52 Potential: 52
Field Value
LMK KEY 9239-9524-4000-0668-3202
ADDRESS1 55 BLAKE CLOSE
ADDRESS2 CANNOCK
ADDRESS3
POSTCODE WS11 5UB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 35
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2021-04-08
LOCAL AUTHORITY E07000192
CONSTITUENCY E14001150
COUNTY
LODGEMENT DATE 2021-04-08
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 19
ENVIRONMENT IMPACT POTENTIAL 52
ENERGY CONSUMPTION CURRENT 789
ENERGY CONSUMPTION POTENTIAL 351
CO2 EMISSIONS CURRENT 9.8
CO2 EMISS CURR PER FLOOR AREA 133
CO2 EMISSIONS POTENTIAL 4.4
LIGHTING COST CURRENT 102
LIGHTING COST POTENTIAL 68
HEATING COST CURRENT 1768
HEATING COST POTENTIAL 890
HOT WATER COST CURRENT 197
HOT WATER COST POTENTIAL 116
TOTAL FLOOR AREA 74
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 55 BLAKE CLOSE, CANNOCK
LOCAL AUTHORITY LABEL Cannock Chase
CONSTITUENCY LABEL Cannock Chase
POSTTOWN CANNOCK
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2021-04-08 08:58:51
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100031615925
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000005
Address display
Nation ew