Energy Performance Certificate

25 Armstrong Cottages, NE69 7BA

EPC Report

Energy rating

Current: 52 E | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 32 | Potential: 50
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 50 Potential: 50
Field Value
LMK KEY 9237-9326-3200-0532-7202
ADDRESS1 25 Armstrong Cottages
ADDRESS2
ADDRESS3
POSTCODE NE69 7BA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 52
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2023-06-02
LOCAL AUTHORITY E06000057
CONSTITUENCY E14001397
COUNTY
LODGEMENT DATE 2023-06-05
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 50
ENERGY CONSUMPTION CURRENT 491
ENERGY CONSUMPTION POTENTIAL 322
CO2 EMISSIONS CURRENT 10
CO2 EMISS CURR PER FLOOR AREA 83
CO2 EMISSIONS POTENTIAL 6.8
LIGHTING COST CURRENT 273
LIGHTING COST POTENTIAL 185
HEATING COST CURRENT 2912
HEATING COST POTENTIAL 2033
HOT WATER COST CURRENT 371
HOT WATER COST POTENTIAL 222
TOTAL FLOOR AREA 125
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 53
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 53% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 25 Armstrong Cottages
LOCAL AUTHORITY LABEL Northumberland
CONSTITUENCY LABEL North Northumberland
POSTTOWN BAMBURGH
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2023-06-05 18:08:17
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 19
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100110577695
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000001
Address display