Energy Performance Certificate

10, Maesyderi, Pentre-Cwrt, SA44 5DJ

EPC Report

Energy rating

Current: 22 F | Potential: 91 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 22 F Current: 22 F 91 B Potential: 91 B

Environmental impact (CO₂)

Current: 21 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 21 Current: 21 75 Potential: 75
Field Value
LMK KEY 9229-2898-7802-9496-9191
ADDRESS1 10, Maesyderi
ADDRESS2 Pentre-Cwrt
ADDRESS3
POSTCODE SA44 5DJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 22
POTENTIAL ENERGY EFFICIENCY 91
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2016-10-18
LOCAL AUTHORITY W06000010
CONSTITUENCY W07000087
COUNTY
LODGEMENT DATE 2016-10-18
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 21
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 563
ENERGY CONSUMPTION POTENTIAL 29
CO2 EMISSIONS CURRENT 8.0
CO2 EMISS CURR PER FLOOR AREA 148
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 77
LIGHTING COST POTENTIAL 38
HEATING COST CURRENT 1088
HEATING COST POTENTIAL 582
HOT WATER COST CURRENT 108
HOT WATER COST POTENTIAL 142
TOTAL FLOOR AREA 54
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.8
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 10, Maesyderi, Pentre-Cwrt
LOCAL AUTHORITY LABEL Carmarthenshire
CONSTITUENCY LABEL Caerfyrddin
POSTTOWN LLANDYSUL
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2016-10-18 19:21:10
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 10004849998
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew