Energy Performance Certificate

54 OAKSIDE COURT, LANGSHOTT, HORLEY, RH6 9XR

EPC Report

Energy rating

Current: 71 C | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 C Current: 71 C 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 56 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 Current: 56 65 Potential: 65
Field Value
LMK KEY 9206-3004-3207-6599-3200
ADDRESS1 54 OAKSIDE COURT
ADDRESS2 LANGSHOTT
ADDRESS3 HORLEY
POSTCODE RH6 9XR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 71
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2021-03-10
LOCAL AUTHORITY E07000211
CONSTITUENCY E14001201
COUNTY
LODGEMENT DATE 2021-03-10
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 56
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 385
ENERGY CONSUMPTION POTENTIAL 303
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 65
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 53
LIGHTING COST POTENTIAL 53
HEATING COST CURRENT 381
HEATING COST POTENTIAL 243
HOT WATER COST CURRENT 158
HOT WATER COST POTENTIAL 158
TOTAL FLOOR AREA 42
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 80
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 80% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 6.5
FLOOR HEIGHT 2.26
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 54 OAKSIDE COURT, LANGSHOTT, HORLEY
LOCAL AUTHORITY LABEL Reigate and Banstead
CONSTITUENCY LABEL Dorking and Horley
POSTTOWN HORLEY
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2021-03-10 20:18:05
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 68146296
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000008
Address display
Nation ew