Energy Performance Certificate

80, Manor Road, GU14 7HL

EPC Report

Energy rating

Current: 46 E | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 E Current: 46 E 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 41 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 Current: 41 73 Potential: 73
Field Value
LMK KEY 9178-6031-7275-2434-2914
ADDRESS1 80, Manor Road
ADDRESS2
ADDRESS3
POSTCODE GU14 7HL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 46
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2014-05-13
LOCAL AUTHORITY E07000092
CONSTITUENCY E14001063
COUNTY
LODGEMENT DATE 2014-05-13
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 41
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 306
ENERGY CONSUMPTION POTENTIAL 116
CO2 EMISSIONS CURRENT 7.7
CO2 EMISS CURR PER FLOOR AREA 59
CO2 EMISSIONS POTENTIAL 3.0
LIGHTING COST CURRENT 135
LIGHTING COST POTENTIAL 68
HEATING COST CURRENT 1328
HEATING COST POTENTIAL 768
HOT WATER COST CURRENT 187
HOT WATER COST POTENTIAL 79
TOTAL FLOOR AREA 130
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 25 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 80, Manor Road
LOCAL AUTHORITY LABEL Rushmoor
CONSTITUENCY LABEL Aldershot
POSTTOWN FARNBOROUGH
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2014-05-13 18:09:08
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100060545530
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000008
Address display
Nation ew