Energy Performance Certificate

Gingerbread Cottage, Whitehall, Scorrier, TR16 5BB

EPC Report

Energy rating

Current: 24 F | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 24 F Current: 24 F 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 18 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 18 Current: 18 75 Potential: 75
Field Value
LMK KEY 9178-4915-6249-9154-9974
ADDRESS1 Gingerbread Cottage
ADDRESS2 Whitehall
ADDRESS3 Scorrier
POSTCODE TR16 5BB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 24
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2014-11-13
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001554
COUNTY
LODGEMENT DATE 2014-11-19
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 18
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 460
ENERGY CONSUMPTION POTENTIAL 67
CO2 EMISSIONS CURRENT 8.6
CO2 EMISS CURR PER FLOOR AREA 116
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 85
LIGHTING COST POTENTIAL 47
HEATING COST CURRENT 1621
HEATING COST POTENTIAL 519
HOT WATER COST CURRENT 163
HOT WATER COST POTENTIAL 99
TOTAL FLOOR AREA 74
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 20
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 20% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.9
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Gingerbread Cottage, Whitehall, Scorrier
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL Truro and Falmouth
POSTTOWN REDRUTH
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2014-11-19 16:41:32
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 10023683329
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000009
Address display
Nation ew