Energy Performance Certificate

35, Redlands Road, Hadley, TF1 5LW

EPC Report

Energy rating

Current: 76 C | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 C Current: 76 C 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 75 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 Current: 75 85 Potential: 85
Field Value
LMK KEY 9178-4071-7293-4366-0924
ADDRESS1 35, Redlands Road
ADDRESS2 Hadley
ADDRESS3
POSTCODE TF1 5LW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 76
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-07-13
LOCAL AUTHORITY E06000020
CONSTITUENCY E14001541
COUNTY
LODGEMENT DATE 2016-07-14
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 75
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 151
ENERGY CONSUMPTION POTENTIAL 86
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 27
CO2 EMISSIONS POTENTIAL 1.6
LIGHTING COST CURRENT 91
LIGHTING COST POTENTIAL 69
HEATING COST CURRENT 449
HEATING COST POTENTIAL 452
HOT WATER COST CURRENT 147
HOT WATER COST POTENTIAL 111
TOTAL FLOOR AREA 106
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 4
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 68
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 68% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 35, Redlands Road, Hadley
LOCAL AUTHORITY LABEL Telford and Wrekin
CONSTITUENCY LABEL Telford
POSTTOWN TELFORD
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2016-07-14 09:56:30
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 19
LOW ENERGY FIXED LIGHT COUNT 13
UPRN 452091560
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000005
Address display
Nation ew