Energy Performance Certificate

11, Southlands Court, WA7 4SA

EPC Report

Energy rating

Current: 76 C | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 C Current: 76 C 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 98 | Potential: 98
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 98 Current: 98 98 Potential: 98
Field Value
LMK KEY 9166-2829-7920-9028-9551
ADDRESS1 11, Southlands Court
ADDRESS2
ADDRESS3
POSTCODE WA7 4SA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 76
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-12-21
LOCAL AUTHORITY E06000006
CONSTITUENCY E14001455
COUNTY
LODGEMENT DATE 2018-12-21
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 98
ENVIRONMENT IMPACT POTENTIAL 98
ENERGY CONSUMPTION CURRENT 210
ENERGY CONSUMPTION POTENTIAL 210
CO2 EMISSIONS CURRENT 1.2
CO2 EMISS CURR PER FLOOR AREA 37
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 34
LIGHTING COST POTENTIAL 34
HEATING COST CURRENT 188
HEATING COST POTENTIAL 188
HOT WATER COST CURRENT 101
HOT WATER COST POTENTIAL 101
TOTAL FLOOR AREA 34
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Flat rate charging, TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 75
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Flat rate charging, TRVs
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 75% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.46
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 11, Southlands Court
LOCAL AUTHORITY LABEL Halton
CONSTITUENCY LABEL Runcorn and Helsby
POSTTOWN RUNCORN
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2018-12-21 09:27:33
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 4
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100010231648
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000002
Address display
Nation ew