Energy Performance Certificate

37, Regency Close, TN22 1DS

EPC Report

Energy rating

Current: 49 E | Potential: 66 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 E Current: 49 E 66 D Potential: 66 D

Environmental impact (CO₂)

Current: 49 | Potential: 71
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 71 Potential: 71
Field Value
LMK KEY 9138-1987-7259-6718-4954
ADDRESS1 37, Regency Close
ADDRESS2
ADDRESS3
POSTCODE TN22 1DS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 49
POTENTIAL ENERGY EFFICIENCY 66
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2018-11-17
LOCAL AUTHORITY E07000065
CONSTITUENCY E14001212
COUNTY
LODGEMENT DATE 2018-11-23
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 71
ENERGY CONSUMPTION CURRENT 438
ENERGY CONSUMPTION POTENTIAL 241
CO2 EMISSIONS CURRENT 3.2
CO2 EMISS CURR PER FLOOR AREA 75
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 62
LIGHTING COST POTENTIAL 34
HEATING COST CURRENT 545
HEATING COST POTENTIAL 383
HOT WATER COST CURRENT 230
HOT WATER COST POTENTIAL 95
TOTAL FLOOR AREA 43
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 20
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Timber frame, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, mains gas, Room heaters, electric
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 20% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 5.1
FLOOR HEIGHT 2.2
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 37, Regency Close
LOCAL AUTHORITY LABEL Wealden
CONSTITUENCY LABEL East Grinstead and Uckfield
POSTTOWN UCKFIELD
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2018-11-23 18:21:06
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100060139946
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000008
Address display