Energy Performance Certificate

38 High Road, Stapleford, SG14 3NW

EPC Report

Energy rating

Current: 30 F | Potential: 42 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 F Current: 30 F 42 E Potential: 42 E

Environmental impact (CO₂)

Current: 77 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 Current: 77 81 Potential: 81
Field Value
LMK KEY 9136-1729-6500-0756-7206
ADDRESS1 38 High Road
ADDRESS2 Stapleford
ADDRESS3
POSTCODE SG14 3NW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 30
POTENTIAL ENERGY EFFICIENCY 42
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2026-01-06
LOCAL AUTHORITY E07000242
CONSTITUENCY E14001393
COUNTY
LODGEMENT DATE 2026-01-06
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 77
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 237
ENERGY CONSUMPTION POTENTIAL 187
CO2 EMISSIONS CURRENT 2.4
CO2 EMISS CURR PER FLOOR AREA 22
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 122
LIGHTING COST POTENTIAL 122
HEATING COST CURRENT 3337
HEATING COST POTENTIAL 2841
HOT WATER COST CURRENT 571
HOT WATER COST POTENTIAL 474
TOTAL FLOOR AREA 107
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 52
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 38 High Road, Stapleford
LOCAL AUTHORITY LABEL East Hertfordshire
CONSTITUENCY LABEL North East Hertfordshire
POSTTOWN HERTFORD
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2026-01-06 12:44:49
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 23
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 100080736306
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000006
Address display
Nation ew