Energy Performance Certificate

28 ALMA ROAD, TRURO, TR1 3PG

EPC Report

Energy rating

Current: 59 D | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 57 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 Current: 57 88 Potential: 88
Field Value
LMK KEY 9130-2104-9090-2000-9415
ADDRESS1 28 ALMA ROAD
ADDRESS2 TRURO
ADDRESS3
POSTCODE TR1 3PG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2020-11-04
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001554
COUNTY
LODGEMENT DATE 2020-11-23
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 57
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 252
ENERGY CONSUMPTION POTENTIAL 49
CO2 EMISSIONS CURRENT 3.4
CO2 EMISS CURR PER FLOOR AREA 44
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 79
LIGHTING COST POTENTIAL 79
HEATING COST CURRENT 501
HEATING COST POTENTIAL 312
HOT WATER COST CURRENT 356
HOT WATER COST POTENTIAL 70
TOTAL FLOOR AREA 79
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 78
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 78% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 28 ALMA ROAD, TRURO
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL Truro and Falmouth
POSTTOWN TRURO
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2020-11-23 13:42:26
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100040039199
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000009
Address display
Nation ew