Energy Performance Certificate

15 SAXON CLOSE, ROXTON, MK44 3EP

EPC Report

Energy rating

Current: 48 E | Potential: 105 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 105 A Potential: 105 A

Environmental impact (CO₂)

Current: 54 | Potential: 105
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 Current: 54 105 Potential: 105
Field Value
LMK KEY 9130-2002-6090-2090-5881
ADDRESS1 15 SAXON CLOSE
ADDRESS2 ROXTON
ADDRESS3
POSTCODE MK44 3EP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 48
POTENTIAL ENERGY EFFICIENCY 105
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2020-11-12
LOCAL AUTHORITY E06000055
CONSTITUENCY E14001384
COUNTY
LODGEMENT DATE 2020-11-12
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 54
ENVIRONMENT IMPACT POTENTIAL 105
ENERGY CONSUMPTION CURRENT 306
ENERGY CONSUMPTION POTENTIAL -46
CO2 EMISSIONS CURRENT 4.3
CO2 EMISS CURR PER FLOOR AREA 52
CO2 EMISSIONS POTENTIAL -0.6
LIGHTING COST CURRENT 64
LIGHTING COST POTENTIAL 64
HEATING COST CURRENT 990
HEATING COST POTENTIAL 409
HOT WATER COST CURRENT 393
HOT WATER COST POTENTIAL 268
TOTAL FLOOR AREA 83
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 15 SAXON CLOSE, ROXTON
LOCAL AUTHORITY LABEL Bedford
CONSTITUENCY LABEL North Bedfordshire
POSTTOWN ROXTON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2020-11-12 20:28:53
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100080036025
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000006
Address display
Nation ew