Energy Performance Certificate

42a, High Street, CT6 5LH

EPC Report

Energy rating

Current: 45 E | Potential: 66 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 E Current: 45 E 66 D Potential: 66 D

Environmental impact (CO₂)

Current: 28 | Potential: 51
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 28 Current: 28 51 Potential: 51
Field Value
LMK KEY 9128-1007-6233-4191-0984
ADDRESS1 42a, High Street
ADDRESS2
ADDRESS3
POSTCODE CT6 5LH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 45
POTENTIAL ENERGY EFFICIENCY 66
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2019-07-12
LOCAL AUTHORITY E07000106
CONSTITUENCY E14001282
COUNTY
LODGEMENT DATE 2019-07-12
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 28
ENVIRONMENT IMPACT POTENTIAL 51
ENERGY CONSUMPTION CURRENT 537
ENERGY CONSUMPTION POTENTIAL 308
CO2 EMISSIONS CURRENT 6.9
CO2 EMISS CURR PER FLOOR AREA 91
CO2 EMISSIONS POTENTIAL 3.9
LIGHTING COST CURRENT 87
LIGHTING COST POTENTIAL 67
HEATING COST CURRENT 1028
HEATING COST POTENTIAL 508
HOT WATER COST CURRENT 304
HOT WATER COST POTENTIAL 304
TOTAL FLOOR AREA 76
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Controls for high heat retention storage heaters
MULTI GLAZE PROPORTION 83
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Controls for high heat retention storage heaters
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 42a, High Street
LOCAL AUTHORITY LABEL Canterbury
CONSTITUENCY LABEL Herne Bay and Sandwich
POSTTOWN HERNE BAY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2019-07-12 22:38:21
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100060834076
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000008
Address display
Nation ew