Energy Performance Certificate

46 COBBETT ROAD, TWICKENHAM, TW2 6EN

EPC Report

Energy rating

Current: 1 G | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 1 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 Current: 1 88 Potential: 88
Field Value
LMK KEY 9120-3003-0202-1579-7204
ADDRESS1 46 COBBETT ROAD
ADDRESS2 TWICKENHAM
ADDRESS3
POSTCODE TW2 6EN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2021-02-12
LOCAL AUTHORITY E09000027
CONSTITUENCY E14001556
COUNTY
LODGEMENT DATE 2021-02-13
TRANSACTION TYPE Non-marketed sale
ENVIRONMENT IMPACT CURRENT 1
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 969
ENERGY CONSUMPTION POTENTIAL 54
CO2 EMISSIONS CURRENT 12
CO2 EMISS CURR PER FLOOR AREA 171
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 79
LIGHTING COST POTENTIAL 79
HEATING COST CURRENT 2192
HEATING COST POTENTIAL 331
HOT WATER COST CURRENT 152
HOT WATER COST POTENTIAL 68
TOTAL FLOOR AREA 71
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 46 COBBETT ROAD, TWICKENHAM
LOCAL AUTHORITY LABEL Richmond upon Thames
CONSTITUENCY LABEL Twickenham
POSTTOWN TWICKENHAM
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2021-02-13 10:30:08
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100022332428
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000007
Address display
Nation ew