Energy Performance Certificate

40 Coopers Yard, Paynes Park, SG5 1AR

EPC Report

Energy rating

Current: 62 D | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 D Current: 62 D 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 66 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 Current: 66 65 Potential: 65
Field Value
LMK KEY 9109-7304-1002-1320-2096
ADDRESS1 40 Coopers Yard
ADDRESS2 Paynes Park
ADDRESS3
POSTCODE SG5 1AR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 62
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Flat
BUILT FORM Detached
INSPECTION DATE 2024-10-29
LOCAL AUTHORITY E07000099
CONSTITUENCY E14001289
COUNTY
LODGEMENT DATE 2024-10-29
TRANSACTION TYPE
ENVIRONMENT IMPACT CURRENT 66
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 219
ENERGY CONSUMPTION POTENTIAL 222
CO2 EMISSIONS CURRENT 3.2
CO2 EMISS CURR PER FLOOR AREA 37
CO2 EMISSIONS POTENTIAL 3.2
LIGHTING COST CURRENT 166
LIGHTING COST POTENTIAL 190
HEATING COST CURRENT 832
HEATING COST POTENTIAL 480
HOT WATER COST CURRENT 540
HOT WATER COST POTENTIAL 281
TOTAL FLOOR AREA 86
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 92
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 92% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 15.09
FLOOR HEIGHT 2.2
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 40 Coopers Yard, Paynes Park
LOCAL AUTHORITY LABEL North Hertfordshire
CONSTITUENCY LABEL Hitchin
POSTTOWN HITCHIN
CONSTRUCTION AGE BAND England and Wales: 2007-2011
LODGEMENT DATETIME 2024-10-29 18:08:00
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 10023317909
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000006
Address display
Nation ew