Energy Performance Certificate

Pickwell House, Hogsgate, Moulton, PE12 6QH

EPC Report

Energy rating

Current: 89 B | Potential: 92 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 89 B Current: 89 B 92 A Potential: 92 A

Environmental impact (CO₂)

Current: 91 | Potential: 93
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 91 Current: 91 93 Potential: 93
Field Value
LMK KEY 9100-2847-7198-9504-5331
ADDRESS1 Pickwell House
ADDRESS2 Hogsgate
ADDRESS3 Moulton
POSTCODE PE12 6QH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 89
POTENTIAL ENERGY EFFICIENCY 92
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2014-11-03
LOCAL AUTHORITY E07000140
CONSTITUENCY E14001487
COUNTY
LODGEMENT DATE 2014-11-03
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 91
ENVIRONMENT IMPACT POTENTIAL 93
ENERGY CONSUMPTION CURRENT 47
ENERGY CONSUMPTION POTENTIAL 38
CO2 EMISSIONS CURRENT 2.4
CO2 EMISS CURR PER FLOOR AREA 8
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 158
LIGHTING COST POTENTIAL 109
HEATING COST CURRENT 1161
HEATING COST POTENTIAL 1099
HOT WATER COST CURRENT 319
HOT WATER COST POTENTIAL 289
TOTAL FLOOR AREA 289
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 4
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 56
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 56% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Pickwell House, Hogsgate, Moulton
LOCAL AUTHORITY LABEL South Holland
CONSTITUENCY LABEL South Holland and The Deepings
POSTTOWN SPALDING
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2014-11-03 17:08:55
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 85
LOW ENERGY FIXED LIGHT COUNT 48
UPRN 10002552348
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000004
Address display
Nation ew