Energy Performance Certificate

Flat 5, 40 Hamilton Road, RG1 5RD

EPC Report

Energy rating

Current: 42 E | Potential: 68 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 E Current: 42 E 68 D Potential: 68 D

Environmental impact (CO₂)

Current: 49 | Potential: 47
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 47 Potential: 47
Field Value
LMK KEY 9070-2807-3320-2099-2145
ADDRESS1 Flat 5
ADDRESS2 40 Hamilton Road
ADDRESS3
POSTCODE RG1 5RD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 42
POTENTIAL ENERGY EFFICIENCY 68
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2021-12-13
LOCAL AUTHORITY E06000038
CONSTITUENCY E14001438
COUNTY
LODGEMENT DATE 2022-01-06
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 47
ENERGY CONSUMPTION CURRENT 366
ENERGY CONSUMPTION POTENTIAL 380
CO2 EMISSIONS CURRENT 3.9
CO2 EMISS CURR PER FLOOR AREA 62
CO2 EMISSIONS POTENTIAL 4.0
LIGHTING COST CURRENT 56
LIGHTING COST POTENTIAL 62
HEATING COST CURRENT 1022
HEATING COST POTENTIAL 564
HOT WATER COST CURRENT 349
HOT WATER COST POTENTIAL 181
TOTAL FLOOR AREA 63
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Timber frame, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.2
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 5, 40 Hamilton Road
LOCAL AUTHORITY LABEL Reading
CONSTITUENCY LABEL Reading Central
POSTTOWN READING
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2022-01-06 08:53:25
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 310073844
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000008
Address display
Nation ew