Energy Performance Certificate

3, The Oaklands, CV4 9SY

EPC Report

Energy rating

Current: 48 E | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 42 | Potential: 71
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 71 Potential: 71
Field Value
LMK KEY 9068-7005-7209-1384-4920
ADDRESS1 3, The Oaklands
ADDRESS2
ADDRESS3
POSTCODE CV4 9SY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 48
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2014-01-16
LOCAL AUTHORITY E08000026
CONSTITUENCY E14001182
COUNTY
LODGEMENT DATE 2014-01-16
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 71
ENERGY CONSUMPTION CURRENT 297
ENERGY CONSUMPTION POTENTIAL 136
CO2 EMISSIONS CURRENT 9.2
CO2 EMISS CURR PER FLOOR AREA 57
CO2 EMISSIONS POTENTIAL 4.3
LIGHTING COST CURRENT 121
LIGHTING COST POTENTIAL 83
HEATING COST CURRENT 1566
HEATING COST POTENTIAL 985
HOT WATER COST CURRENT 269
HOT WATER COST POTENTIAL 91
TOTAL FLOOR AREA 161
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 15
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 52
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 52% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.34
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3, The Oaklands
LOCAL AUTHORITY LABEL Coventry
CONSTITUENCY LABEL Coventry South
POSTTOWN COVENTRY
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2014-01-16 11:17:49
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 21
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 100070711197
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000005
Address display
Nation ew