Energy Performance Certificate

19, Firth Fields, Davenham, CW9 8JB

EPC Report

Energy rating

Current: 58 D | Potential: 67 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 67 D Potential: 67 D

Environmental impact (CO₂)

Current: 46 | Potential: 54
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 54 Potential: 54
Field Value
LMK KEY 9068-4975-6272-5183-7944
ADDRESS1 19, Firth Fields
ADDRESS2 Davenham
ADDRESS3
POSTCODE CW9 8JB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 67
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2017-12-16
LOCAL AUTHORITY E06000050
CONSTITUENCY E14001361
COUNTY
LODGEMENT DATE 2018-01-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 54
ENERGY CONSUMPTION CURRENT 245
ENERGY CONSUMPTION POTENTIAL 198
CO2 EMISSIONS CURRENT 16
CO2 EMISS CURR PER FLOOR AREA 43
CO2 EMISSIONS POTENTIAL 13
LIGHTING COST CURRENT 141
LIGHTING COST POTENTIAL 141
HEATING COST CURRENT 2859
HEATING COST POTENTIAL 2456
HOT WATER COST CURRENT 137
HOT WATER COST POTENTIAL 137
TOTAL FLOOR AREA 371
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 99
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 9
LOW ENERGY LIGHTING 99
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 99% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.51
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 19, Firth Fields, Davenham
LOCAL AUTHORITY LABEL Cheshire West and Chester
CONSTITUENCY LABEL Mid Cheshire
POSTTOWN NORTHWICH
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2018-01-10 17:04:14
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 130
LOW ENERGY FIXED LIGHT COUNT 129
UPRN 100010184511
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000002
Address display
Nation ew