Energy Performance Certificate

14 MAYFAIR COURT, WAKEFIELD, WF2 8WL

EPC Report

Energy rating

Current: 63 D | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 D Current: 63 D 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 50 | Potential: 68
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 Current: 50 68 Potential: 68
Field Value
LMK KEY 9060-2012-4000-2320-7661
ADDRESS1 14 MAYFAIR COURT
ADDRESS2 WAKEFIELD
ADDRESS3
POSTCODE WF2 8WL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 63
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Flat
BUILT FORM Enclosed End-Terrace
INSPECTION DATE 2020-10-22
LOCAL AUTHORITY E08000036
CONSTITUENCY E14001560
COUNTY
LODGEMENT DATE 2020-10-30
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 50
ENVIRONMENT IMPACT POTENTIAL 68
ENERGY CONSUMPTION CURRENT 389
ENERGY CONSUMPTION POTENTIAL 241
CO2 EMISSIONS CURRENT 3.8
CO2 EMISS CURR PER FLOOR AREA 66
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 66
LIGHTING COST POTENTIAL 77
HEATING COST CURRENT 168
HEATING COST POTENTIAL 208
HOT WATER COST CURRENT 650
HOT WATER COST POTENTIAL 204
TOTAL FLOOR AREA 58
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 73
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 73% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.46
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 14 MAYFAIR COURT, WAKEFIELD
LOCAL AUTHORITY LABEL Wakefield
CONSTITUENCY LABEL Wakefield and Rothwell
POSTTOWN WAKEFIELD
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2020-10-30 12:06:29
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 63164021
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000003
Address display
Nation ew