Energy Performance Certificate

14, Rochefort Drive, SS4 1HT

EPC Report

Energy rating

Current: 49 E | Potential: 69 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 E Current: 49 E 69 C Potential: 69 C

Environmental impact (CO₂)

Current: 47 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 67 Potential: 67
Field Value
LMK KEY 9058-8072-7293-2454-6980
ADDRESS1 14, Rochefort Drive
ADDRESS2
ADDRESS3
POSTCODE SS4 1HT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 49
POTENTIAL ENERGY EFFICIENCY 69
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2014-07-15
LOCAL AUTHORITY E07000075
CONSTITUENCY E14001501
COUNTY
LODGEMENT DATE 2014-07-23
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 67
ENERGY CONSUMPTION CURRENT 304
ENERGY CONSUMPTION POTENTIAL 178
CO2 EMISSIONS CURRENT 5.7
CO2 EMISS CURR PER FLOOR AREA 57
CO2 EMISSIONS POTENTIAL 3.4
LIGHTING COST CURRENT 114
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 1204
HEATING COST POTENTIAL 947
HOT WATER COST CURRENT 76
HOT WATER COST POTENTIAL 76
TOTAL FLOOR AREA 99
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 7
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, plus solar
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 7% of fixed outlets
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY
SOLAR WATER HEATING FLAG Y
MECHANICAL VENTILATION natural
ADDRESS 14, Rochefort Drive
LOCAL AUTHORITY LABEL Rochford
CONSTITUENCY LABEL Southend East and Rochford
POSTTOWN ROCHFORD
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2014-07-23 17:40:04
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100090591794
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000006
Address display
Nation ew