Energy Performance Certificate

23, High Street, Dragonby, DN15 0BE

EPC Report

Energy rating

Current: 42 E | Potential: 112 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 E Current: 42 E 112 A Potential: 112 A

Environmental impact (CO₂)

Current: 11 | Potential: 109
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 11 Current: 11 109 Potential: 109
Field Value
LMK KEY 9058-0044-6225-5305-7974
ADDRESS1 23, High Street
ADDRESS2 Dragonby
ADDRESS3
POSTCODE DN15 0BE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 42
POTENTIAL ENERGY EFFICIENCY 112
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-05-15
LOCAL AUTHORITY E06000013
CONSTITUENCY E14001128
COUNTY
LODGEMENT DATE 2015-05-28
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 11
ENVIRONMENT IMPACT POTENTIAL 109
ENERGY CONSUMPTION CURRENT 428
ENERGY CONSUMPTION POTENTIAL -73
CO2 EMISSIONS CURRENT 12
CO2 EMISS CURR PER FLOOR AREA 157
CO2 EMISSIONS POTENTIAL -0.8
LIGHTING COST CURRENT 62
LIGHTING COST POTENTIAL 48
HEATING COST CURRENT 965
HEATING COST POTENTIAL 390
HOT WATER COST CURRENT 258
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 74
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, anthracite
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL anthracite
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.48
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 23, High Street, Dragonby
LOCAL AUTHORITY LABEL North Lincolnshire
CONSTITUENCY LABEL Brigg and Immingham
POSTTOWN SCUNTHORPE
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2015-05-28 07:09:35
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100050208708
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000003
Address display
Nation ew