Energy Performance Certificate

11 White Mill Drive, Pocklington, YO42 2FF

EPC Report

Energy rating

Current: 79 C | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 C Current: 79 C 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 81 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 81 Current: 81 82 Potential: 82
Field Value
LMK KEY 9051-3053-1208-2685-7204
ADDRESS1 11 White Mill Drive
ADDRESS2 Pocklington
ADDRESS3
POSTCODE YO42 2FF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 79
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-08-15
LOCAL AUTHORITY E06000011
CONSTITUENCY E14001250
COUNTY
LODGEMENT DATE 2025-08-18
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 81
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 112
ENERGY CONSUMPTION POTENTIAL 100
CO2 EMISSIONS CURRENT 2.1
CO2 EMISS CURR PER FLOOR AREA 20
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 116
LIGHTING COST POTENTIAL 81
HEATING COST CURRENT 569
HEATING COST POTENTIAL 572
HOT WATER COST CURRENT 230
HOT WATER COST POTENTIAL 230
TOTAL FLOOR AREA 106
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and at least two room thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 69
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and at least two room thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.39
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 11 White Mill Drive, Pocklington
LOCAL AUTHORITY LABEL East Riding of Yorkshire
CONSTITUENCY LABEL Goole and Pocklington
POSTTOWN YORK
CONSTRUCTION AGE BAND England and Wales: 2012-2021
LODGEMENT DATETIME 2025-08-18 11:26:46
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 10091610901
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000003
Address display
Nation ew