Energy Performance Certificate

39, Anglesey Road, SR3 3EF

EPC Report

Energy rating

Current: 49 E | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 E Current: 49 E 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 43 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 Current: 43 88 Potential: 88
Field Value
LMK KEY 9038-7091-7269-3515-6910
ADDRESS1 39, Anglesey Road
ADDRESS2
ADDRESS3
POSTCODE SR3 3EF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 49
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-01-17
LOCAL AUTHORITY E08000024
CONSTITUENCY E14001295
COUNTY
LODGEMENT DATE 2015-01-29
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 43
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 480
ENERGY CONSUMPTION POTENTIAL 95
CO2 EMISSIONS CURRENT 4.6
CO2 EMISS CURR PER FLOOR AREA 85
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 49
LIGHTING COST POTENTIAL 37
HEATING COST CURRENT 534
HEATING COST POTENTIAL 389
HOT WATER COST CURRENT 440
HOT WATER COST POTENTIAL 65
TOTAL FLOOR AREA 54
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 39, Anglesey Road
LOCAL AUTHORITY LABEL Sunderland
CONSTITUENCY LABEL Houghton and Sunderland South
POSTTOWN SUNDERLAND
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-01-29 13:52:08
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 45025917
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000001
Address display
Nation ew