Energy Performance Certificate
The Old Granary, Main Street, Ashby De La Launde, LN4 3JG
Energy rating
Current: 50 E | Potential: 61 D
Environmental impact (CO₂)
Current: 44
| Potential: 52
| Field | Value |
|---|---|
| LMK KEY | 9031-3012-5209-0112-8200 |
| ADDRESS1 | The Old Granary |
| ADDRESS2 | Main Street |
| ADDRESS3 | Ashby De La Launde |
| POSTCODE | LN4 3JG |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | E |
| POTENTIAL ENERGY RATING | D |
| CURRENT ENERGY EFFICIENCY | 50 |
| POTENTIAL ENERGY EFFICIENCY | 61 |
| PROPERTY TYPE | House |
| BUILT FORM | Detached |
| INSPECTION DATE | 2022-01-17 |
| LOCAL AUTHORITY | E07000139 |
| CONSTITUENCY | E14001476 |
| COUNTY | — |
| LODGEMENT DATE | 2022-01-27 |
| TRANSACTION TYPE | Marketed sale |
| ENVIRONMENT IMPACT CURRENT | 44 |
| ENVIRONMENT IMPACT POTENTIAL | 52 |
| ENERGY CONSUMPTION CURRENT | 205 |
| ENERGY CONSUMPTION POTENTIAL | 156 |
| CO2 EMISSIONS CURRENT | 18 |
| CO2 EMISS CURR PER FLOOR AREA | 49 |
| CO2 EMISSIONS POTENTIAL | 15 |
| LIGHTING COST CURRENT | 190 |
| LIGHTING COST POTENTIAL | 190 |
| HEATING COST CURRENT | 3103 |
| HEATING COST POTENTIAL | 3109 |
| HOT WATER COST CURRENT | 158 |
| HOT WATER COST POTENTIAL | 99 |
| TOTAL FLOOR AREA | 373 |
| ENERGY TARIFF | dual |
| MAINS GAS FLAG | N |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 2 |
| MAIN HEATING CONTROLS | Time and temperature zone control |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double, known data |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 4 |
| NUMBER HABITABLE ROOMS | 11 |
| NUMBER HEATED ROOMS | 11 |
| LOW ENERGY LIGHTING | 98 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Average |
| FLOOR DESCRIPTION | Solid, insulated |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| WALLS DESCRIPTION | Sandstone or limestone, as built, insulated (assumed) |
| WALLS ENERGY EFF | Good |
| WALLS ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Room heaters, dual fuel (mineral and wood) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, insulated |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and underfloor heating, oil |
| MAINHEAT ENERGY EFF | Poor |
| MAINHEAT ENV EFF | Average |
| MAINHEATCONT DESCRIPTION | Time and temperature zone control |
| MAINHEATC ENERGY EFF | Very Good |
| MAINHEATC ENV EFF | Very Good |
| LIGHTING DESCRIPTION | Low energy lighting in 98% of fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | oil (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.45 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | mechanical, supply and extract |
| ADDRESS | The Old Granary, Main Street, Ashby De La Launde |
| LOCAL AUTHORITY LABEL | North Kesteven |
| CONSTITUENCY LABEL | Sleaford and North Hykeham |
| POSTTOWN | LINCOLN |
| CONSTRUCTION AGE BAND | England and Wales: before 1900 |
| LODGEMENT DATETIME | 2022-01-27 15:09:23 |
| TENURE | owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | 42 |
| LOW ENERGY FIXED LIGHT COUNT | 41 |
| UPRN | 10006503151 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2022.csv |
| COUNTRY | England |
| REGION | E12000004 |
| Address display | — |
| Nation | ew |