Energy Performance Certificate

23, Marsh Road, Terrington St. Clement, PE34 4HX

EPC Report

Energy rating

Current: 31 F | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 31 F Current: 31 F 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 25 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 25 Current: 25 75 Potential: 75
Field Value
LMK KEY 9028-4058-7283-0202-0980
ADDRESS1 23, Marsh Road
ADDRESS2 Terrington St. Clement
ADDRESS3
POSTCODE PE34 4HX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 31
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2012-07-12
LOCAL AUTHORITY E07000146
CONSTITUENCY E14001405
COUNTY
LODGEMENT DATE 2012-07-12
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 25
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 431
ENERGY CONSUMPTION POTENTIAL 104
CO2 EMISSIONS CURRENT 8.4
CO2 EMISS CURR PER FLOOR AREA 105
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 67
LIGHTING COST POTENTIAL 45
HEATING COST CURRENT 1114
HEATING COST POTENTIAL 485
HOT WATER COST CURRENT 439
HOT WATER COST POTENTIAL 101
TOTAL FLOOR AREA 80
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 85
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.62
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 23, Marsh Road, Terrington St. Clement
LOCAL AUTHORITY LABEL King's Lynn and West Norfolk
CONSTITUENCY LABEL North West Norfolk
POSTTOWN KING'S LYNN
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2012-07-12 11:34:13
TENURE
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100090981159
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000006
Address display
Nation ew